Insulation & Flexible Ducts

Insulation & Flexible Ducts

We stand for quality, safety & credibility, so you could be trust us fully about architectural working process.

ELASTOMERIC INSULATION SHEETS

Elastomeric Rubber Foam Insulation Sheets

Wide range of production

The most suitable size for duct isolation; wıth sheet width 100cm, 120cm and 150cm production in 7 different thickness intervals.

Helps to absorb vibrations that occur in the channel through its elastic structure.

Reduces the use of duct tape at round and square section channels and reduce scrap rates.

Pa-Flex contact adhesive helps to get productive results in duct installation.

Reduces th scrap rate 2-3%.

Operating temperature is between -40 / + 120 °C.

Has as a density of 42-55 kg/m³

Since thermal conductivity coefficient of the elastomeric material is low it reduces the heat transfer significantly (λ ≤ 0,035 W / mK).

Description

Elastomeric Rubber foams which have high thermal insulation value are resistant to water and steam as well as bear resistance characteristic against the UV (Ultraviolet) rays, harsh weather conditions and oils. Elastomeric Rubber Foam allowing the ease of installation and use with its high flexibility does not allow forming of fungus and mold on it.

Heat permeability coefficient constitutes the most important insulation. Due to the stable air incarceratedin the closed cells of PA-FLEX and low heat conductivity of the elastomeric material a significant reduction is provided in heat transfer.The surface temperature is reached to the ideal value by means of the low insulation value (0,035)

The materials and cellular structure of the PA-FLEX which is manufactured in accordance with the suitable density (7500) and closed cell rate ensures long term insulation efficiency and resists to water vapor permeability.

Pa-flex elastomeric rubber foam is resistant to fire.In case of fire it does not allow the flames to progressin the vertical and horizontal direction. By means of this feature it meets all the values prescribed for fire safety and it is an insulation material you can use in your buildings and installations confidently .

Pa-Flex Elastomeric Rubber foam isolations are rubber-based, have a smooth cell structure with closed pores and are produced in sheet and tube form.

PRODUCT DETAILS

 Sheet Width
(1000 mm)
Sheet Width
(1200 mm)
Sheet Width
(1500 mm)
Thickness (mm)m²/Rollm²/Rollm²/Roll
6 mm30 m²36 m²45 m²
9 mm20 m²24 m²30 m²
13 mm14 m²16,8 m²21 m²
19 mm10 m²12 m²15 m²
25 mm8 m²9,6 m²12 m²
32 mm6 m²7,2 m²9 m²
50 mm4 m²4,8 m²6 m²

Due to the high strength , reinforced ,self-adhesive feature it saves time and labor.

Due to its adhesive feature, it contrebutes to sealing and reduces the workmanship errors.

Reduces the scrap rate to 2-3%.

The most suitable size for duct insulation ; 100cm, 120cm and 150cm width sheet, and production in 7 different thickness intervals.

Due to its elastic structure, help relieve vibration appearing in the ducts.

Operating temperature is between -40 / + 120 ° C.

Has as a density of 42-55 kg/m³.

Since thermal conductivity coefficient of the elastomeric material is low it reduces the heat transfer significantly (λ ≤ 0,035 W / mK).

Description

 Sheet Width
(1000 mm)
Sheet Width
(1200 mm)
Sheet Width
(1500 mm)
Thickness (mm)m²/Rollm²/Rollm²/Roll
6 mm30 m²36 m²45 m²
9 mm20 m²24 m²30 m²
13 mm14 m²16,8 m²21 m²
19 mm10 m²12 m²15 m²
25 mm8 m²9,6 m²12 m²
32 mm6 m²7,2 m²9 m²
50 mm4 m²4,8 m²6 m²

The most suitable size for duct insulation; 100cm, 120cm and 150cm width sheets, production in 7 different thickness intervals ; Due to its elastic structure, help relieve vibration appearing in the ducts.

Reduces the use of the band and reduces the waste rate in round and square cross-section channels.

Reduces the scrap rate to 2-3%.

Operationg temperature is between -40 / + 120 ° C.

It has a density of 42-55 kg/m³.

Covered with aluminum foil; The power of self-adhesive feature allows saving labor and time.

High quality aluminum and polyester laminated surface provides resistance to UV rays and external factors.

The most suitable size for duct insulation; 100cm, 120cm and 150cm width sheets, production in 7 different thickness intervals ;

Due to its elastic structure, help relieve vibration appearing in the ducts..

Reduces the scrap rate to 2-3%.

Operationg temperature is between -40 / + 120 ° C.

It has a density of 42-55 kg/m³.

Description

Sheet Width
(1000 mm)
Sheet Width
(1200 mm)
Sheet Width
(1500 mm)
Thiskness (mm)m²/Rollm²/Rollm²/Roll
6 mm30 m²36 m²45 m²
9 mm20 m²24 m²30 m²
13 mm14 m²16,8 m²21 m²
19 mm10 m²12 m²15 m²
25 mm8 m²9,6 m²12 m²
32 mm6 m²7,2 m²9 m²
50 mm4 m²4,8 m²6 m²

ELASTOMERIC INSULATION PIPES

The fluid is used to prevent condensation with the effect of external conditions and to minimize heat losses.

Description

During the application, the inner surface of the insulation and the installation pipe should be in full contact with each other and no space should be allowed between them. It is caused by the deformation of the insulation during the application, a complete insulation should be made from the bridge. It is necessary to coat immediately.

With a wide range of production, Pa-Flex pipe insulations of 6/9/13/19/25/32 mm wall thickness are produced in a diameter range of 6mm-114mm.

Operating temperature is between -40 / + 120 ° C.

Has as a density of 42-55 kg / m³.

PIPE METRAGE

BSDNMETRIC
inchØ DNmm
1/4″15
1/2″DN1522
3/4″DN2028
1″DN2535
11/4″DN3242
11/2″DN4048
2″DN5060
21/2″DN6576
3″DN8089
4″DN100114
5″DN125140
6″DN150169
8″DN200219
10″DN250273
 
BSDNMETRIC
inchØ DNmm
12″DN300323
14″DN350398
16″DN400406
18″DN450467
20″DN500508
24″DN600610
28″DN700761
32″DN800813
36″DN900914
40″DN10001016
44″DN11001116
48″DN12001219
52″DN13001331
56″DN14001422

SHEET METRAGE (M²/M)

Steel Pipe DiameterPipe Thickness    Insulation Thickness 
inchmetricmm6 mm9 mm13 mm19 mm25 mm32 mm40 mm50 mm60 mm
4″11460.380.390.400.420.440.460.490.520.52
5″14080.460.470.480.50.520.540.570.60.6
6″140100.840.550.560.580.60.620.640.680.68
8″219120.710.720.730.750.770.790.820.850.85
10″273150.880.890.910.920.940.960.991.021.02
12″323181.041.051.061.081.11.121.151.181.18
14″160.380.390.400.420.440.460.490.520.52

IN BOX METRAGE

MetricCooperSteel  Thickness / Total Package 
mminchinch6 mm9 mm13 mm19 mm25 mm32mm
61/4″502360214
85/16″442308194
103/8″1/8″40826217496
121/2″37223616492
155/8″1/4″27019613880
183/4″3/8″226170120745230
227/8″1/2″186138100664432
251″162120905842
281 1/8″3/4″13610280544028
351 3/8″1″1028060422824
421 5/8″1 1/4″926650402422
481 1/2″5242322018
542 1/8″5038301816
602 3/8″2″4834301616
672 5/8″4634221616
763″2 1/2″4232241416
803 1/8″40322012
893 1/2″3″3830201416
1023 1/2″36241814
1084 1/4″34241812
1144 1/2″4″3222181210

AUXILIARY PRODUCTS


It is used to seal elastomeric rubber foam insulation to ventilation ducts and piping.

Pa-Flex is produced as an alternative to contact adhesive-like products.

The drying time and reaction of the glue may change in the atmosphere of the site environment.

After application, surfaces should be fastened.

Maximum adhesion strength is obtained when the process is carried out in accordance with the strength of the drying process.

Products are in 15 kg – 3.2 kg – 1 kg packages.

 

Full sealing with Pa-Flex reinforced rubber bands, preventing condensation on flanges.

PRODUCT
DIMENSIONS
5 cm3mm x 50mm x 15mt
7.5cm3mm x 75mm x 15mt
10cm3mm x 100mm x 15mt

Pa-Flex aluminum foil bands and vapor impermeable insulation applications.

PRODUCTDIMENSIONS
FLAT50mm x 25m
FLAT75mm x 25m
FLAT100mm x 25m
REINFORCED50mm x 25m
REINFORCED75mm x 25m
REINFORCED100mm x 25m

Affordable installation with Pa-Flex PVC bands.

Size -> 50mm x 28 yd

It’s produced with non-combustible rubber impregnation technique.

Pyramid shape was formed by cutting with a special cutting machine.

Due to its open porous structure, sound absorption coefficients are high at high frequencies

It provides an economical solution as a sound insulation rubber.

The sound absorption performance of the product used for sound and heat insulation is very good at medium and high frequencies. It is especially used in air conditioning duct insulation.

It is used for acoustic arrangement and sound insulation when economical product is requested in regions where flame and burning is not a risk